Hauptseite > Fabrication Tuning of Four 748.5 MHz Single Cell SRF Booster Cavities for a 100 mA SRF FEL Injector |
Article | |
Title | Fabrication Tuning of Four 748.5 MHz Single Cell SRF Booster Cavities for a 100 mA SRF FEL Injector |
Author(s) | Cole, Michael ; Peterson, Ed ; Rathke, John ; Schultheiss, Tom |
Affiliation | (AES, Medford, NY) ; (AES, Princeton, New Jersey) |
Publication | 2005 |
In: | 21st IEEE Particle Accelerator Conference, Knoxville, TN, USA, 16 - 20 May 2005, pp.4272 |
Subject category | Accelerators and Storage Rings |
Abstract | Advanced Energy Systems has recently completed the fabrication of four 748.5 MHz single cell superconducting cavities which are to be used in the JLAB FEL SRF Injector Test Stand. During the fabrication process a series of frequency measurements were made and compared to the frequency expected at that point in the fabrication process. Where possible, the cavity was modified either before or during, the next fabrication step to tune the cavity frequency toward the target frequency. The target frequency is calculated making a series of assumptions about the frequency effects of subsequent fabrication and processing steps. |