CERN Accelerating science

Report
Report number KAERI-RR-2183-2001
Title Development of Gas Electron Multiplier(GEM) for digital radiographic system
Author(s) Moon, B S ; Chung, C E ; Lee, J W
Publication Taejon : Korea At. Ernergy Res. Inst., 2000 - 237.
Subject category Detectors and Experimental Techniques
Abstract Two computer programs SHOWFIELD and IMAGEQUAL have been developed. SHOWFIELD is used to draw electric field lines for GEM detectors and IMAGEQUAL is used to study the spatial resolution of x-ray images. Various simulation runs have been carried out using EGS4 to study the characteristics of electrons generated by micro-channel plates and Ar, Xe gases. A prototype GEM detector was developed through this project. The GEM detector is composed of a pair of GEM plates, a micro-channel plate, readout circuit in a gas filled chamber. GEM plate were made in CERN to meet KAERI's design specification and the micro-channel plates were purchased from Proxitronic company.


 Record created 2004-06-30, last modified 2010-03-29


fulltext:
Download fulltext
PDF