CERN Accelerating science

Article
Title Aspects of operational conditions of a double gap prototype RPC for the CMS/LHC experiment
Author(s) Ahn, S H ; Amirikas, R ; Bahk, S Y ; Baik, K M ; Gapienko, V A ; Hong, B ; Hong, S J ; Kim, J Y ; Kim, Y J ; Kim, Y U ; Koo, D G ; Lee, K S ; Lee, S J ; Lim, I T ; Nam, S K ; Pac, M Y ; Park, S ; Rhee, J T ; Seo, S W ; Sim, K S
Affiliation (Detector Lab)
Publication 2001
In: Nucl. Instrum. Methods Phys. Res., A 465 (2001) 447-54
DOI 10.1016/S0168-9002(01)00623-4
Subject category Detectors and Experimental Techniques
Accelerator/Facility, Experiment CERN LHC ; CMS
Abstract This paper presents the results from cosmic ray tests performed in the framework of R&D effort on the forward Resistive Plate Chamber (RPC) for CMS. A double gap RPC of dimensions 50*50 cm/sup 2/ with 2 mm gas gaps was tested. We report data on the use of tetrafluorethane-based gas mixture, with additions of water vapour and SF/sub 6/. Efficiency, time resolution and cross-talk behaviour of the detector were investigated. (8 refs).

Corresponding record in: Inspire
 記錄創建於2001-09-10,最後更新在2011-08-11